CBSE Class 12 Physics · Alternating Current
The Transformer: Working, Turns Ratio and Energy Losses
The construction and principle of a transformer, the ratio of voltages and currents in terms of the turns, numericals on ideal transformers, the causes of energy loss, and why ac and not dc can be transformed.
Why this matters
18 questions, every one of them from board papers. The board asks you to draw a labelled diagram of a step-up transformer, explain its working and derive the ratio of voltages (2023, 2024, 2025, 2026), state the causes of energy loss in a real transformer (2023, 2024), find voltages, currents, turns or power in an ideal transformer (2023, 2024, 2025, 2026), say what stays the same in the two coils (2024), and answer reasoning items on dc supplies, on conservation of energy and on why ac is used (2024, 2025, 2026).
Concept 1 of 4: Construction, principle and the turns ratio
Definition
- Construction: a primary coil of turns and a secondary coil of turns, insulated from each other, wound on a soft-iron core, either one on top of the other or on separate limbs. The core is laminated.
- Principle: mutual induction.
- Derivation outline (ideal transformer): let be the flux in each turn of the core.
- Emf induced in the secondary: . Back emf in the primary: .
- With negligible primary resistance, ; with a small secondary current, .
- Dividing: .
- If no energy is lost, power in = power out: , so .
- The relation rests on three assumptions: small primary resistance and current, the same flux linking both coils, and a small secondary current.
- Step-up: , so and . Step-down: , so and .
- The diagram: draw a closed laminated soft-iron core, the primary on one limb joined to the ac input, the secondary on the other limb joined to the output, and label the core, both coils, , , and .
Ideal transformer
- turns in the primary and the secondary
- primary and secondary voltages
- primary and secondary currents
Worked example
Practise this conceptself-check · 3 quick reps
The same idea in a real exam question:
Example 1 · Alternating Current · Transformers
No labelled diagram
Turning the ratio upside down
Dropping the reason the flux cancels
Concept 2 of 4: Numericals on an ideal transformer
Definition
- ; then from the load () or from the power ().
- Ideal: , so .
- Volts per turn is the same on every winding: .
- The frequency does not change: the output alternates at the frequency of the source.
- If the input is given as , the output is : the same , the amplitude scaled by the turns ratio. Use for the rms value.
Power through an ideal transformer
Worked example
Practise this conceptself-check · 3 quick reps
The same idea in a real exam question:
Example 2 · Alternating Current · Transformers
Changing the frequency
Treating a peak input as rms
Concept 3 of 4: Energy losses in a real transformer
Definition
- An ideal transformer loses no energy. A real one always loses a little, yet a well designed transformer may have an efficiency of more than 95%.
- The board asks for two, three or four causes, so learn all four with the way each is reduced.
| Loss | Cause | How it is reduced |
|---|---|---|
| Flux leakage | Not all the flux of the primary passes through the secondary, because of poor design or air gaps in the core | Wind the primary and secondary one over the other |
| Resistance of the windings | The wires have resistance, so heat is produced in them | Use thick wire in the high current, low voltage winding |
| Eddy currents | The alternating flux induces eddy currents in the iron core, which heat it | Use a laminated coreQ Board 2024 asked for two causes of energy loss in a real transformer. |
| Hysteresis | The magnetisation of the core is reversed again and again, and the energy spent appears as heat | Use a core material with a low hysteresis loss |
Practise this concept3 quick reps
The same idea in a real exam question:
Example 3 · Alternating Current · Transformers
Naming a loss without its remedy
Laminating does not stop flux leakage
Concept 4 of 4: Reasoning questions on transformers and ac supply
Definition
- An ideal transformer keeps the power the same; it raises the voltage only by lowering the current in the same ratio.
- In each answer give the reason, not only yes or no: the reason carries the mark.
| Question | Answer | Reason |
|---|---|---|
| Can a transformer step up or step down a dc supply? | No | A steady current gives a steady flux, which induces no emf in the secondary |
| Does a step-up transformer break the law of conservation of energy? | No | The current is reduced in the same ratio as the voltage is raised, so the output power is not more than the input |
| Can a step-up transformer be used to step down? | Yes | Feed the ac to the coil with more turns; then is less than 1 |
| What stays the same in both coils of an ideal transformer? | The flux in each turn, and the power | Both coils link the same core flux, and no energy is lost; voltage and current change with the turnsQ Board 2024 asked which of current, voltage, power and magnetic flux stay the same. |
| Does a transformer change the frequency? | No | The output alternates at the frequency of the source |
| Why is electrical energy supplied as ac rather than dc? | Ac voltages are easily changed | Transformers change ac voltages easily and efficiently, and ac can be transmitted economically over long distancesQ Board 2026 asked which statement about ac is NOT true; the false one was that ac is less dangerous. |
Practise this concept3 quick reps
The same idea in a real exam question:
Example 4 · Alternating Current · Transformers
Saying 'step-up' means more energy
A true reason that is not the explanation
Summary — formulas & gotchas at a glance
A revision cheat-sheet for the formulas and gotchas above. Click any concept name to jump back to its full explanation.
Formulas (2)
- Construction, principle and the turns ratio
Ideal transformer
- Numericals on an ideal transformer
Power through an ideal transformer
Reference tables (2)
Energy losses in a real transformer4 rows
| Loss | Cause | How it is reduced |
|---|---|---|
| Flux leakage | Not all the flux of the primary passes through the secondary, because of poor design or air gaps in the core | Wind the primary and secondary one over the other |
| Resistance of the windings | The wires have resistance, so heat is produced in them | Use thick wire in the high current, low voltage winding |
| Eddy currents | The alternating flux induces eddy currents in the iron core, which heat it | Use a laminated coreQ Board 2024 asked for two causes of energy loss in a real transformer. |
| Hysteresis | The magnetisation of the core is reversed again and again, and the energy spent appears as heat | Use a core material with a low hysteresis loss |
Reasoning questions on transformers and ac supply6 rows
| Question | Answer | Reason |
|---|---|---|
| Can a transformer step up or step down a dc supply? | No | A steady current gives a steady flux, which induces no emf in the secondary |
| Does a step-up transformer break the law of conservation of energy? | No | The current is reduced in the same ratio as the voltage is raised, so the output power is not more than the input |
| Can a step-up transformer be used to step down? | Yes | Feed the ac to the coil with more turns; then is less than 1 |
| What stays the same in both coils of an ideal transformer? | The flux in each turn, and the power | Both coils link the same core flux, and no energy is lost; voltage and current change with the turnsQ Board 2024 asked which of current, voltage, power and magnetic flux stay the same. |
| Does a transformer change the frequency? | No | The output alternates at the frequency of the source |
| Why is electrical energy supplied as ac rather than dc? | Ac voltages are easily changed | Transformers change ac voltages easily and efficiently, and ac can be transmitted economically over long distancesQ Board 2026 asked which statement about ac is NOT true; the false one was that ac is less dangerous. |
Watch out for (9)
- No labelled diagram→ Construction, principle and the turns ratio
- Turning the ratio upside down→ Construction, principle and the turns ratio
- Dropping the reason the flux cancels→ Construction, principle and the turns ratio
- Changing the frequency→ Numericals on an ideal transformer
- Treating a peak input as rms→ Numericals on an ideal transformer
- Naming a loss without its remedy→ Energy losses in a real transformer
- Laminating does not stop flux leakage→ Energy losses in a real transformer
- Saying 'step-up' means more energy→ Reasoning questions on transformers and ac supply
- A true reason that is not the explanation→ Reasoning questions on transformers and ac supply
Test yourself on Alternating Current
15 past CBSE Class 12 questions from this chapter, timed at 23 minutes and marked the way the exam marks it. You see your score and every answer the moment you finish. Free to start.