HSC Physics · Electromagnetic Induction
Faraday's Laws and Magnetic Flux
Faraday's two laws of electromagnetic induction, magnetic flux and flux linkage, and how to find the e.m.f. induced when the flux through a coil changes.
Why this matters
11 questions. Five were set in board papers: prove the relation between the induced e.m.f. and the rate of change of flux (2018), state Faraday's laws (2025), find the e.m.f. from a flux given as a function of time (2017), the flux linked with a coil of many turns (2023) and the e.m.f. in a search coil pulled out of a field (2024). The textbook adds a square coil in a growing field, a loop whose field is reduced and the electric field set up by a changing field.
Concept 1 of 3: Faraday's two laws of induction
Definition
- First law: whenever the magnetic flux linked with a closed circuit changes, an e.m.f. is induced in the circuit. Also, if a conductor cuts magnetic field lines, an e.m.f. is induced between its ends. The e.m.f. lasts only while the flux is changing. This is a qualitative law.
- Second law: the magnitude of the induced e.m.f. is directly proportional to the rate of change of magnetic flux linked with the circuit, . In SI units the constant is 1. This is a quantitative law.
- Joined with Lenz's law, ; for a coil of N turns with flux through each turn, . The textbook calls this the flux rule. One weber per second is one volt.
- Proof that (the board asks you to prove it): draw a C-shaped frame ABCD in a uniform field normal to its plane, with a wire BC of length sliding on it.
- Step 1: when BC is at distance , the area is , so and .
- Step 2: a charge in BC moves with velocity , so the Lorentz force acts along the wire.
- Step 3: the work done carrying along BC is , so the e.m.f. is .
- Step 4: comparing, in magnitude; with Lenz's law and N turns, .
- A changing field also sets up an electric field round any closed path, (textbook Exercise Q.17). Inside a circular region of changing field, at radius , this gives .
Faraday's law with Lenz's sign
- induced e.m.f., in volt
- number of turns of the coil
- rate of change of flux through one turn, in weber per second
Worked example
Practise this conceptself-check · 4 quick reps
The same idea in a real exam question:
Example 1 · Electromagnetic Induction · Faraday's Laws and Magnetic Flux
Flux instead of change of flux
The proof without its diagram
Leaving out the turns
Concept 2 of 3: Magnetic flux and flux linkage
Definition
- The flux through a small area is , where is the angle between the field and the normal to the area.
- For a uniform field and a flat area A: . If the field is not the same everywhere, the area is split into small pieces and the flux is added (integrated) over them.
- SI unit: the weber (Wb), with 1 Wb = 1 T m².
- Field along the normal (the coil's plane perpendicular to the field): , . Field lying in the plane of the coil: , .
- Flux linkage of a closely wound coil of N turns: . The induced e.m.f. depends on how this changes.
- Flux can be changed by changing B, the area A, or the angle .
Flux and flux linkage
Worked example
Practise this conceptself-check · 3 quick reps
The same idea in a real exam question:
Example 2 · Electromagnetic Induction · Faraday's Laws and Magnetic Flux
Measuring the angle from the plane
Flux when the question asks for flux linkage
Concept 3 of 3: Average e.m.f. from a change of flux
Definition
- Average e.m.f.: .
- Area fixed, field changing: .
- Coil pulled right out of the field (or field switched off): , so .
- Coil turned over, or field reversed: the flux goes from to , so .
- Change every area to m² first: 1 cm² = m².
Average induced e.m.f.
Worked example
Practise this conceptself-check · 3 quick reps
The same idea in a real exam question:
Example 3 · Electromagnetic Induction · Faraday's Laws and Magnetic Flux
Area left in cm²
Forgetting the reversal doubles the change
Summary — formulas & gotchas at a glance
A revision cheat-sheet for the formulas and gotchas above. Click any concept name to jump back to its full explanation.
Formulas (3)
- Faraday's two laws of induction
Faraday's law with Lenz's sign
- Magnetic flux and flux linkage
Flux and flux linkage
- Average e.m.f. from a change of flux
Average induced e.m.f.
Watch out for (7)
- Flux instead of change of flux→ Faraday's two laws of induction
- The proof without its diagram→ Faraday's two laws of induction
- Leaving out the turns→ Faraday's two laws of induction
- Measuring the angle from the plane→ Magnetic flux and flux linkage
- Flux when the question asks for flux linkage→ Magnetic flux and flux linkage
- Area left in cm²→ Average e.m.f. from a change of flux
- Forgetting the reversal doubles the change→ Average e.m.f. from a change of flux
Test yourself on Electromagnetic Induction
10 past MH HSC 12 questions from this chapter, timed at 15 minutes and marked the way the exam marks it. You see your score and every answer the moment you finish. Free to start.